BASSBOSS Ashley NXp8004DL Rack Amplifier

Most orders placed by 2pm ET ship in 3-5 business days
Only at IDJ NOW

Fast Shipping
Most products ship same-day

30-Day Price Protection
Find a lower price, you're covered.

8000+ Reviews
95%+5-star reviews>

30-Day Returns
Don't Like it? Return most items.
nXp amplifiers carry all nX and nXe features plus Protėa DSP and swept load impedance analysis. These amps are designed to meet the most demanding live sound environments and fixed installation sound systems such as stadiums, arenas, performance venues, worship spaces and convention centers. NX Multi-Mode Amplifiers are designed for your most demanding installations. NX amplifiers are trust-worthy, power amplifiers that install and configure into virtually any architecture and sound environment. NX Amplifiers feature Selectable Outputs on each channel so you can connect to virtually any speaker. Select Low Impedance (2, 4, and 8 Ohm), or Constant Voltage (70V or 100V). Start with a 2 or 4-channel nX Series base model and build your way up. Choose from 36 model configurations, available from 75 to 3000 Watts per channel. The nXe Series adds Ethernet control, event scheduler, preset recall, AUX outputs and much more. Add factory options like Dante or CobraNet for network audio integration.
The nXp Series has all the features of nXe, adding Protea DSP and swept load impedance analysis. The unit is a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power is 800W per channel at Low Z, 70V, and 100V mode. There is an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply can auto-detect 110 - 120VAC or 220 - 240VAC mains, and a Neutrik powerCON is used for the AC cord. Each channel has a selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel has a remote DC level control. Input connector is Neutrik XLR/TRS combo jack and Euroblock, while the output connector is Neutrik speakON. The unit has a front panel power switch and level controls that can be disabled. LEDs indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit has an Ethernet control with a real-time clock for event scheduling. It also has a serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The unit has a 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier has a temperature dependent variable speed forced-air cooling.
BASSBOSS Ashley NXp8004DL Rack Amplifier Features:
- Protēa DSP audio processing on inputs and outputs.
- Automatic Feedback Suppressor.
- Auto-Mixer.
- Ambient Noise Compensation.
- Dynamics processing with auto-ducker.
- EQ & crossovers including FIR filters.
- Time alignment and tower delay.
- Scheduled noise-masking with Real-Time Clock.
- Swept AC load-analysis with baseline logging.
- FIR Filter capable, dynamics, gain, equalization, 2×4 or 4×4 matrix mixer, crossover, delay, metering, and signal generator functions for test and noise masking applications.
- Precision swept load impedance monitoring of each amplifier channel.
- Ethernet Control and monitoring of amplifier functions, with front panel COM activity LED.
- Serial data port for use with Ashly remote control devices, or optional RS- 232 converter for third party controllers (INA-1.)
- Use Protea Software to remotely disable all front panel controls, including the on/off switch, for a tamper-proof installation.
- Real-Time Clock with Event Scheduler.
- Instant Standby Mode 30% reduction in power consumption with on/off and Preset Recall, both via contact closure, software control, or event scheduler.
- Programmable power-on delay.
- Aux preamp outputs, and fault condition logic outputs.
- Optional Cobranet or Dante and AES3 digital audio input with passthru.
- Rear panel DIP switches select low impedance (2, 4, and 8 Ohm), constant voltage (70V or 100V), high pass filter, limiter and input gain on each channel.
- Ashly Energy Management System (EMS) for increased efficiency) automatic <1Wsleep-mode (defeatable.)
- Switch mode power supply automatically detects 120V or 240V AC operation.
- Extensive protection circuitry.
- Continuously variable cooling fans.
- Front panel power switch and level controls (can be disabled for security.)
- Multiple internal power supplies provide increased channel separation and reliability.
- Remote DC level control on each input channel (2 RU models only.)
- Genuine Neutrik connectors on 2 RU models for security, safety, and reliability.
- Safety / Compliance: cTUVus, CE, FCC, RoHS.
BASSBOSS Ashley NXp8004DL Product Specifications:
General | |
---|---|
Voltage Gain | Selectable at 26dB, 32dB, 38dB, or 1.4V |
Damping Factor | >250 (8 Ohms load <1kHz) |
Input High Pass Filter | 80Hz 2nd order |
Distortion (SMPTE, typical) | <0.5% |
Distortion (THD-N, typical) | <0.5% (8 Ohms, 10dB below rated power, 20Hz-20kHz) |
Channel Separation | -75dB (dB from full output, 1kHz) |
Signal-to-Noise (20Hz-20kHz, unweighted) | >114dB (all 3.0x models) >111dB (all 1.5x models) >108dB (all 800x models) >105dB (all 400x models) |
Frequency Response | 20Hz-20kHz, +/-0.05dB |
Balanced Input Connector | Euroblock 3.5mm, 1/4" TRS & XLR Combo jack |
Input Impedance | 10k Ohms |
Maximum Input Level | +21dBu |
Speaker Output Connector | Neutrik speakON |
Control Network | Compatible w/ standard 100MB Ethernet |
AUX Output Connector | Balanced Euroblock 3.5mm |
AUX Output Maximum Level | +21dBu |
Remote Standby Contact Closure | Euroblock 3.5mm, close contact to GND for standby mode |
Preset Recall Contact Closure | Euroblock 3.5mm, close contact to GND for preset 1-4 recall |
Data Connection | Euroblock 3.5mm - Gnd, +18V, In, Out |
Fault Condition Logic Outputs | Fault indicated by loss of 1Hz "heartbeat" pulse signal |
Remote DC Level Control | Euroblock 3.5mm - Gnd, CV, V+ per input |
Attenuators (per channel) | Front panel, software, offset link group, and remote. Fully off = Mute |
Amplifier Protection | Inrush current limitation, temperature monitoring, output over-power protection, mains fuses |
Cooling | Continuously variable temperature controlled axial fan(s) |
Environmental | 32-113 deg F, (0-45 deg, C) (noncondensing) |
Power Requirements (50 - 60Hz) | |
Nominal (Automatic Sensing SMPS) | 110 - 120VAC / 220 - 240VAC |
Operating Range | 70 - 135VAC / 140 - 270VAC |
Minimum power-up | 85VAC / 170VAC |
Power Cable Connector | 20A powerCON (32A powerCON 3.04 model only) |
Weights and Dimensions | |
Unit Weight 4004/8004: | 25.9lbs (11.7kg) |
Shipping Weight 4004/8004: | 32.4lbs (14.8kg) |
Unit Dimensions (all models) | 19"W x 3.5"H x 16.84"D (483mm x 89mm x 428mm) |
Shipping Dimensions | 24.5"W x 22"H x 5.25"D (622mm x 559mm x 133mm) |
Each Ashley NXp8004DL Retail Box Includes:
(1) BASSBOSS Ashley NXp8004DL Rack Amplifier